+ 空调主机
+ 空调末端
 
 
  空调主机
 
 
Water Source Heat Pump (With Scroll Compressor)

Geothermal Ground Source Heat Pump
Water Source Heat Pump
Water to Water Heat Pump
Heating Only
Heating+Cooling+Hot Water

Our Brand: LUTE and LYTTE and we have got the honor of CHINA FAMOUS BRAND.
Introduction:
1.LVTE company design, manufacture Scroll Geothermal Heat Pump, Screw Geothermal Heat Pump, Residential Geothermal Heat Pump and kinds of Ground Source Heat Pump.
2. These heat pump are all used for building heating and cooling to be as the central air conditioning system, It has high COP and saving energy, also can make hot water for daily life use.
3. Geothermal heat pumps form LVTE company have large cooling range from 1tons to 1500tons, and also large heating range.
4. LVTE company Geothermal Heat Pumps units has been gained many design patents in china.
5. Cooperate with world famous opponents like Copeland, Bitzer, Danfoss, Refcomp etc.


Ground/Water source heat pump system can adopt water of lake, river, underground and ground heat source; With compressor and electrical power, it can transmit heat from water into the room in winter, and from room into water in summer to achieve the purpose of air conditioning. Heat from the ground is absorbed at low temperatures into a fluid inside a loop of pipe (a ground loop) buried underground. The fluid then passes through a compressor that raises it to a higher temperature, which can then heat water for the heating and hot water circuits of the house. The cooled ground-loop fluid passes back into the ground where it absorbs further energy from the ground in a continuous process as long as heating is required.
Normally the loop is laid flat or coiled in trenches about two metres deep, but if there is not enough space in your garden you can install a vertical loop down into the ground to a depth of up to 100 metres for a typical domestic home.
Heat pumps have some impact on the environment as they need electricity to run, but the heat they extract from the ground, the air, or water is constantly being renewed naturally.
Environmental-friendly:In heating mode, it can replace the boiler system to avoid smoke-pollution. In cooling mode, it can avoid noise and leaf mold from cooling tower to protect environment.
Energy saving:In winter, user can get 5KW heat power with 1kw electrical power. In summer, uses can get more than 6KW cooling power with 1kw electrical power. The efficiency is 3-4 times as that of electrical heater.
Space-saving:No need of Boiler and relevant equipment, by which can save space.
Water-Saving:Cooling or heating can be realize by discharging or absorbing power into the water; water source will not be consumed neither be polluted.
Money-saving:Cooling or heating can be realized by one system; its investment is 1/2-2 of that of traditional equipment.

Notes:
1.Cooling Standard Conditions:User side water inlet/outlet 12℃/7℃;Water source side inlet/outlet 30℃/35℃.
2.Heating Standard Conditions: User side hot water inlet/outlet 40℃/45℃;Water source side inlet/outlet 15℃/7℃; Max. Hot Water Output: R410a-55°C; R134a-65°C; R407c-55°C;
3.Heat recovery equipments can be added for free sanitary hot water.

Notes:
1.Cooling Standard Conditions:User side water inlet/outlet 12℃/7℃;Water source side inlet/outlet 30℃/35℃.
2.Heating Standard Conditions: User side hot water inlet/outlet 40℃/45℃;Water source side inlet/outlet 15℃/7℃; Max. Hot Water Output: R410a-55°C; R134a-65°C; R407c-55°C;
3.Heat recovery equipments can be added for free sanitary hot water.

Notes:
1.Cooling Standard Conditions:User side water inlet/outlet 12℃/7℃;Water source side inlet/outlet 30℃/35℃.
2.Heating Standard Conditions: User side hot water inlet/outlet 40℃/45℃;Water source side inlet/outlet 15℃/7℃; Max. Hot Water Output: R410a-55°C; R134a-65°C; R407c-55°C;
3.Heat recovery equipments can be added for free sanitary hot water.

Notes:
1.Cooling Standard Conditions:User side water inlet/outlet 12℃/7℃;Water source side inlet/outlet 30℃/35℃.
2.Heating Standard Conditions: User side hot water inlet/outlet 40℃/45℃;Water source side inlet/outlet 15℃/7℃; Max. Hot Water Output: R410a-55°C; R134a-65°C; R407c-55°C;
3.Heat recovery equipments can be added for free sanitary hot water.

 
上一个:Air Cooled Chiller (With Screw Compressor)   下一个:Geothermal Ground Source Heat Pump (Modular Type with Scroll Compressor)
 
HOME  | ABOUT  | PRODUCTS  | NEWS  | PROJECT  | SCIENTIFIC AND TECHNOLOGICAL  | SERVICE  | NETWORK  | MESSAGE  | CONTACT  | JOBS  |

Copyright© All Rights Reserved: Shandong LVTE Air Conditioning System Co.,Ltd.     鲁ICP备05033970号 

Central Air Conditioning&Refrigerant Equipments Products:

GROUND SOURCE HEAT PUMP, AIR SOURCE HEAT PUMP, AIR COOLED CHILLER, WATER COOLED CHILLER, FAN COIL UNIT, AIR HANDLING UNIT, PACKAGED AIR CONDITIONER, CONDENSING UNIT, EVAPORATOR, CONDENSER, REFRIERANT ACCESSORIES